60mA,100KVp Light Mobile X-Ray Machine - Exporter & Manufacturer, Delhi, India
 
Home Page
Company Profile
Showroom
  X-Ray Equipments
 
MEDILUX SYSTEMS
60mA,100KVp Light Mobile X-Ray Machine
To inquire, Select Product/s & Click on

Product Code : 01

[Select]
Product Specification

60mA,100KVp Light Mobile X-Ray Machine:
Medilux X-Ray Systems has the power to meet all your Radiography and Fluoroscopy requirements. A wide range of KVp and mA settings coupled with single-phase mains operations makes it ideally suited for diagnostic centers, nursing homes and hospitals.

Ergonomic Design Features:

  • Single Phase (2 Pulse) X-Rays Generator.
  • Maximum Rating 60 mA at 100 KVp (4.8 KW) as per ISI 7620.
  • Independant KVp, mA and time techniques for better radiographic results.
  • Booster transformer for constant mA output.
  • Tube Overload Protector to ensure longer tube life.
  • Line On Off Switch simultaneously acts as Coarse Compensator switch.
  • 15 position Voltage Compensator Switch for voltage compensation in the range 180 to 250 volts ± 24 volts.
  • 12-position KVp switch selects KVp in 12 uniform steps ranging from 45 to 100KVp.
  • Technic switch permits one of the following mA selections:
    20 mA, 40 mA and 60 mA.
  • Radiograph Timer: A 24 position switch permits exposure time selections from 0.06 to 10 seconds.
  • Stationary anode BEL DSA-3 / equivalent imported tube.X-Ray LED glows during exposure period.
  • Tube overload LED glows in case selected exposure factors are in excess of X-Ray tube exposure rating.
  • mA meter: Radiograph actual mA valve is indicated on 0-100 mA analogue scale.
  • High Voltage Silicon Rectifier for consistent results and low system losses.

Compatible With Light Weight Portable / Mobile Stand:

  • Highly maneuverable to reach the patient in the OT, General Wards and ICU.
  • The low height (1.8 meter) of the stand allows the unit to enter lifts & doors.
  • Light Weight (100 Kg. Including X-Rays generator) easy to dismantle stand.

Power Demand at rated output: Single Phase, 50 HZ and 4.8 KW.
Maximum allowable line resistance in 230 volts line is 1.0 Ohms.

Other Products
100mA,100KVp Diagnostic X-Ray Generator
100mA,100KVp Diagnostic X-Ray Generator
Dental X-Ray System
Dental X-Ray System
Micro Controlled Based X-ray Timer
Micro Controlled Based X-ray Timer
300mA,100KVp Diagnostic X-Ray Machine
300mA,100KVp Diagnostic X-Ray Machine
Horizontal Bucky Table
Horizontal Bucky Table
X-Ray System
X-Ray System
 
<< Back